Home Contact Sitemap login Checkout

S Squared innovations
  • Home
  • Products
    • Products
    • Johnson Controls
      • Johnson Controls
      • S2N2C Gateway
      • S2N2D Gateway
      • S2N2E Gateway
      • S2USB485 Interface
      • S2N2Scan
      • S2485Splitter
      • S2USB485DiagN2
      • S2UI28
    • Building Automation
    • Industrial Converters
    • Lighting Controls
      • Lighting Controls
      • Lighting Projects
        • Lighting Projects
        • High Bay Retro Fit
        • Exterior Down Lighting
        • S2HBwRGBW - High Bay Retrofit Module
        • GE TLC Lighting Controls Upgrade
        • Douglas Lighting Controls MC-6000 Based Replacement
      • S2BACLightDPConfig
      • S2SWDP8
      • S2BACLightDP
  • Services
  • Ordering
  • Clients
  • Company
  • Contact
  • Johnson Controls
  • Building Automation
  • Industrial Converters
  • Lighting Controls
    • Lighting Projects
    • S2BACLightDPConfig
    • S2SWDP8
    • S2BACLightDP
Home/Products/Lighting Controls/S2BACLightDP Print This Page


S2BACLightDP - S2 Douglas/Panasonic Lighting Relay Controller


Overview


The S2BACLightDP is an intelligent lighting relay controller designed to control twenty-four (24) Aromat/Panasonic/Douglas Lighting Relays (WR-6221, WR-6161, etc) used primarily in commercial lighting control applications.  The S2BACLightDP also provides support for eight (8) configurable Group Inputs, two (2) HVAC and DC Compatible Binary Inputs, along with multiple communication interfaces for standalone and/or integration in the site's Bus Building Management System (BMS).  


S2BACLightDP was designed as a Douglas Lighting Controls Replacement Solution


The S2BACLightDP can be used as direct replacement to Douglas Lighting's older WRS-2224 Lighting Scanner, but with more features and functionality while maintaining the same size of the original WRS-2224 device.  In fact we are currently the only manufacturer that offers a directly compatible Douglas controller along with supporting Douglas switches and other Douglas products.   Below are links to the S2BACLightDP device along with a comparison between our device and the WRS-2224.   Additionally the S2BACLightDP can be used as to upgrade/replacement for many other Douglas Controllers such as the WR-8812, WR-8824, WTS-4181, WTP-4408, WR-8801, MC-6416, etc.  Effectively, the S2BACLightDP can be used as a Douglas Lighting Controller replacement solution.


Relay Availability  - Yes, Douglas direct replacement and compatible relays are available.


Please note that although Douglas Lighting is no longer in business, the relays they offered were made by other manufacturers and were labelled as Douglas.  Consequently, there are several other vendors that offer the same or directly compatible relays allowing Douglas and other 2-wire relay lighting control system customers to maintain their existing systems and in doing so maintain their capital investment.   The latter cannot be understated, as the cost to remove and reinstall another lighting control system can be substantial along with being highly disruptive to the area lighting and occupants.  As a reference, it takes only a few hours to replacing/upgrade an existing Douglas WRS-2224 lighting system with our S2BACLightDP device.


S2BACLightDP can be used with non Douglas Based Lighting Control systems


Although the S2BACLightDP was designed to replace/upgrade the Douglas controllers, the S2BACLightDP can be used to upgrade other lighting control systems or used on its own in standalone or (Bacnet, Ethernet, etc) networked applications..  To date the S2BACLightDP has successfully been used to upgrade GE Total Lighting Control (TLC) and LC&D (now owned by Acurity) installations.  The resulting upgrade solution maintained all of the electrical infrastructure and in doing so the customer realized substantial savings (GE customer saved in excess of $300K) with virtually no disruption to their lighting areas or those within. 


GE (and equivalent) RR7 and RR9 Relay Support


The S2BACLightDP was designed to directly support the Douglas/Panasonic/Aromat and other 2-wire Lighting relays, however, with a simple add-on plug, the S2BACLightDP can now support GE RR7 (3-wire) or RR9 (5-wire) relays as well.   In fact, the add-o module allows S2BACLightDP installations to mix and match both GE and Douglas/Panasonic/Aromat relays on the same S2BACLightDP controller.


S2BACLightDP Part Number Versions and Protocol Support


All S2BACLightDP Versions use the same hardware and are differentiated primarily by the communication protocols that are supported by the respective S2BACLightDP part number.  However, all part number/version can be field changed with a simple and fast firmware change.  it is noted that there is no extra charge for requesting a different firmware version than what was originally ordered and so customers can migrate or try different firmware versions without concern. 

Field firmware updates or changes is done via the S2BACLightDP's USB interface and a Windows based Computer/laptop. No extra or specialty software is needed other than the firmware image to be installed.  The entire firmware update process takes approximately 5-10 seconds.



S2BACLightDP Windows Configuration Application


To assist the installer with the configuration process of the S2BACLightDP devices, we have released a Free Windows based application.  The application can be directly connected to the S2BACLightDP device's MSTP interface (via a RS485/MSTP interface such as our S2USB485), or anywhere onto the site's BMS Network (Bacnet IP or MSTP ).  Please view our dedicated webpage on this application for more information along with a quick start guide link (S2BACLightDPConfig).


Proudly designed, manufactured, and supported in Edmonton/Calgary, AB, Canada

Specifications


Part Numbers:

  • S2BACLightDP-MSTP (Bacnet MSTP)
  • S2BACLightDP-BIP (Bacnet IP)
  • S2BACLightDP-DMX (Avail Feb 2025)
  • S2BACLightDP-N2 (Special request)
  • S2BACLightDP-ModbusRTU (Special request)
  • S2BACLightDP-ModbusTCP (Special request)

On Board Interfaces

  • One (1) 10/100 Mb/s Ethernet Interface
  • One (1) Electrically isolated Half-Duplex RS-485 Interface
  • One (1) High Speed USB Interface
  • One (1) DALI – Digital Addressable Lighting Interface
  • One (1) Expansion Port for Dimming Controllers, etc.

Power Requirements:

  • 24 V AC/DC 60 Hz @ 300 mA
  • Current requirement varies with the number of relays connected

Environment:

  • Temperature 0 C to +60 C
  • Humidity: 10 - 95 % RH (non-condensing)

Dimensions:

  • 6.38”L x 4.25”W x 1.72” H 
  • 16.2cm L x 10.8cm W x 4.4cm H

Outputs / Relays Support:

  • Twenty-Four (24) Panasonic/Aromat/Douglas WR-6221, WR-6161 or compatible 2-wire latching relays
  • Maximum 3 relays per Output
  • GE RR7/RR9 Relay Support with an add-on Plug

 Inputs:

  • Eight (8) Douglas Compatible (pulse) Group Inputs with momentary switch support via an expansion board
  • Two (2) Optically isolated Dry Contact, HVAC compatible (12-24 V AC/DC) with local +12VDC for external sensors (motion, PIR, light level).

Mounting Options:

  • All versions come standard with Magnetic Standoffs
  • Optional DIN Adapter for DIN Rail Mounting
  • Optional DIN Enclosure like the Douglas WRS-2224

Documents:

  • Cut Sheet
  • Wiring Diagram
  • Feature Comparison with the WRS-2224
  • S2BacLightDP Wiring Connection to Douglas Switches
  • S2BacLightDP Binary Input Wiring Examples